Cash Drawer Wiring & Control Codes
The following table shows connector wiring and
control codes for "solenoid only" receipt
printer-triggered cash drawers.
|
Pin |
Star SP300,
SP500, TSP600, TSP700, SP2000
|
Star DP8340 |
Star SP200 |
Epson (ESCPOSTM) |
Ithaca |
| 1 |
Ground |
Ground |
Ground |
Not Connected |
CD2- |
| 2 |
CD1- |
CD1- |
CD1- |
CD1- |
CD1 Sense |
| 3 |
CD Drive+ (+24V) |
CD Drive+ (+12V) |
CD Drive+ (+24V) |
CD1 Sense |
Ground |
| 4 |
CD Drive+ (+24V) |
CD Drive+ (+12V) |
CD Drive+ (+24V) |
CD Drive+ (+24V) |
CD Drive+ (+24V) |
| 5 |
CD2- |
CD2- |
Not Connected |
CD2- |
CD1- |
| 6 |
CD1 Sense |
Ground |
Not Connected |
Ground |
Not Connected |
| Drawer 1
Open Code(s) |
<7> 1 |
<7> 1 |
<7> 1 |
<27> <112>
<0> <48> |
<27> <120>
<1> |
| Alternate
Drawer 1 Open Code(s) |
<28> 2 |
<28> 2 |
<28> 2 |
<27> <112>
<0> <64> <240> 3 |
(N/A) |
| Autocutter
Code(s) 4 |
<27> <100>
<48> |
(N/A) |
<27> <100>
<48> |
<27> <105> |
<27> <80>
<00> |
| Alternate
Autocutter Code(s) 4 |
<27> <100>
<49> |
(N/A) |
<27> <100>
<49> |
(N/A) |
(N/A) |
|
1
|
Deferred command. Code is inserted into
data buffer and trips the drawer whenever
the character is queued for printing from
the buffer.
|
|
2
|
Immediate. Drawer is immediately tripped
independent of the data buffer.
|
|
3
|
Extended duration trigger pulse.
|
|
4
|
Applicable only for printers equipped with
autocutter.
|
|
|
Control codes are decimal ASCII surrounded
by brackets (<>).
|
|
|
Many newer printers can be configured to
emulate the Epson / ESCPOSTM
control codes.
|
|